2 weeks, 6 days ago electronics nablopomo
The other night, as I was putting the children to bed, the doorbell rang. And again - and again, and again, and again.
Wondering what emergency could necessitate this frantic bell-pushing, I rushed down the stairs and flung open the front door to see... nothing. But the doorbell continued to ring.
I pressed the bell-push myself, to see if it was stuck; at this point the ringing stopped, so I shrugged, assumed it must have just got stuck somehow, and went back upstairs to tend to the children.
Later the same evening, the bell sounded again - but this time it stopped almost immediately, and since I could see from the window there was nobody outside, I turned my attention to other things.
When I did eventually figure out the cause, it was not what I expected!
Over the next few days, the doorbell didn't ring by itself again - but all was not right, because when it did ring, the upstairs sounder didn't sound and, as a consequence, people ringing the doorbell couldn't tell it was working (some of the signal from the upstairs sounder is fed into the speaker by the bellpush to provide some feedback that the system is working).
Time to do some debugging...
Poking a multimeter into the upstairs sounder quickly showed that it was getting no power. At the other end of the wiring, poking the power supply showed that it was working fine - unsurprising since the rest of the system was working fine. So where was the issue? Well. The upstairs sounder is connected by a Cat5 cable, but this is joined at a couple of places by couplers, like the one in the image above, which looks like this inside:

At one of these, I found that there was power on the incoming wires, but not the outgoing wires. Curious, as the whole purpose of this coupler is to join them together! Dismantling the coupler revealed the reason...

In case it's not clear from the picture: that oozy mess is (the remains of) a tiny slug - that had presumably slithered in through one of the openings for the wires, found its way to the circuit board, and promptly shorted out some of the connections (causing the bell to ring). It had then (I guess) been somewhat electrolysed, and also caused the copper traces to corrode (leaving the green residue visible in the picture). None of this was particularly good for the functioning of the coupler (or the slug, for that matter) - the corrosion of the copper must have disconnected the power; removing the slug revealed it was not in a good state at all.

Fortunately, replacing a coupler is not hard, and doing so restored our doorbell to full working order.